Basic Info.
Clapboard
without Clapboard
Medium Material
Fiberglass
Filtration Grade
Medium Filter
Housing Serve Lige
15 Years
Element Serve Life
6000~8000 Hours
Filtration Performance
From 5 μm to 0.01μm
Maxi. Operate Pressure
1.0MPa
Operate Temperature
1.5~80ºC
Resistance Corrosion
Inside and Outside
Parts
Dp Indicator, Auto Drain, Sight Glass
Diversion Fin Design on Element Top Cap
Less Pressure Loss
Quality Complies with
ISO 8573-1:2010
Transport Package
Brown Inner Box & Cardboard
Specification
Dimension: 162 X 151X 676mm
Product Description
How to choose right filter for Your Air Compressor System?When you're working with air compressors, air purification and filtration is an critical part of maintenance. Compressed air filters play an important role in your industrial air compressor system. Choosing the right filter not only increases the efficiency of your unit, but it can also reduce energy costs and protect your employees from harmful chemicals and particulates.
However, does all air filter work for your compressed air system? Well it is depending on your working conditions, the project you're completing and how often you use your equipment, you'll need to make an precise choice. This guide will detail how air compressor filters work, why they're important, what type of air compressor filter to buy and when you should replace it.Assess the requirements of your application. Different industry require different solution. | | Any specific micron of filtration performance you required? |
What type of filtration is needed? Coalecent filter material removes solid and liquied contaminants from gas streams. Particulate filter media removes solid from gas streams. Absorber media removes hydrocarbon vapors from gas streams. |
|
|
|
|
|
What are the working conditions of your application? Mainly criteria of consider : Flow, working pressure, temperature,pressure loss,material of structure (stainless steel, aluminum alloy, mild steel, carbon steel) | |
Filter flow rate from how much SCFM? Pressure drop should be less than **bar? For saving the cost and protect environment. | |
|
|
|
|
|
Feature & Benefit- The air quality provided complies with ISO 8573-1:2010 (International Standard for Compressed Air Quality);
- The performance of the coalescing filter that has been strictly tested meets the requirements of ISO 12500-1;
- The performance of the dust filter tested in accordance with the ISO 8573 series of test methods;
-Suitable for all compressed air applications and all compressor types;87.12
- In order to save energy, money and environment, the pressure loss starts from low and keeps it low;
-Low lifetime cost;
-In the relative environment of coalescing filter and dust filter, the filter element enjoys 6000-8000 hours of compressed air quality assurance, and the activated carbon filter element is 2000-3000 hours;
-All YUKA compressed air filter housings have a 15-year housing warranty.
7 Grades Filter Element: PF/AO/AA/AX/ACS/AR/AARPF | AO | AA | AX | ACS | AR | AAR |
As a primary filter, particles whose diameter more than 5μm can be remove,the maxi. residual oil content is negligible | High efficiency general protection, dust particles, water mist & oil mist whose diameter more than 1μm can be removed, the residual content of oil mist does not exceed 0.6mg/m³ (21ºC),1ppm(w). | High effiency oil remove filtration, dust particles, water mist and oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.01mg/m³(21ºC),0.01ppm(w) | Ultra-efficient filtration, dust particles, water mist&oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.001mg/m³(21ºC),0.001ppm(w) | Dust particles whose diameter more than 0.01μm, oil vapor &odor can be removed, the maxi. resident content of oil vapor does not exceed 0.003mg/m³(21ºC),0.003ppm(w) | Dust particles whose diameter more than 1μm can be removed | Dust particles whose diameter more than 0.01μm can be removed |
Technical SpecificationThe flow rate below is the treatment capacity of compressed air under rated working pressure 7 barg (100psi g).
For application in other working pressure, please refer to the correction factors.Model | Pipe size | Flow rates | Dimension (mm) |
L/S | m3/min | scfm | W(Width) | D(Depth) | H(Height) | A | B | C(clearance for housing) |
YD017 | RC1/2" | 16.7 | 1.0 | 35.3 | 89 | 79 | 246 | 40 | 186 | 118 |
YD025 | RC3/4" | 25.0 | 1.5 | 53.0 | 89 | 79 | 246 | 40 | 186 | 118 |
YD030 | RC1/2" | 30.0 | 1.8 | 63.6 | 89 | 79 | 280 | 40 | 220 | 158 |
YD035 | RC3/4" | 33.3 | 2.0 | 70.6 | 89 | 79 | 280 | 40 | 220 | 158 |
YD058 | RC3/4" | 46.7 | 2.8 | 98.9 | 120 | 110 | 377 | 55 | 276 | 195 |
YD068 | RC1" | 60.0 | 3.6 | 127.1 | 120 | 110 | 377 | 55 | 276 | 195 |
YD080 | RC1" | 80.0 | 4.8 | 169.5 | 120 | 110 | 477 | 55 | 377 | 290 |
YD145 | RC2" | 120.0 | 7.2 | 254.2 | 120 | 110 | 477 | 55 | 377 | 290 |
YD220 | RC1-1/2" | 200.0 | 12.0 | 423.7 | 162 | 151 | 676 | 64 | 566 | 480 |
YD260 | RC2" | 233.3 | 14.0 | 494.4 | 162 | 151 | 676 | 64 | 566 | 480 |
YD330 | RC2" | 267.2 | 16.0 | 564.8 | 162 | 151 | 984 | 64 | 875 | 780 |
YD360 | RC2-1/2" | 317.3 | 19.0 | 670.7 | 162 | 151 | 984 | 64 | 875 | 780 |
YD405 | RC2-1/2" | 367.4 | 22.0 | 776.6 | 200 | 189 | 757 | 78 | 634 | 560 |
YD430 | RC3" | 467.6 | 28.0 | 988.4 | 200 | 189 | 1012 | 78 | 634 | 560 |
YD620 | RC3" | 620.0 | 37.2 | 1313.6 | 200 | 189 | 1012 | 78 | 889 | 780 |
Technical requirements | Maximum operating pressure: 10 barg Operating temperature: 1.5°C~80°C. |
Pressure | Barg | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Psig | 15 | 29 | 44 | 59 | 73 | 87 | 100 | 116 | 131 | 145 | 160 | 174 | 189 | 203 | 219 | 232 |
Correction factor | 0.38 | 0.53 | 0.65 | 0.76 | 0.85 | 0.93 | 1.00 | 1.07 | 1.13 | 1.19 | 1.23 | 1.31 | 1.36 | 1.41 | 1.46 | 1.51 |
YUKA CertificatesYUKA Patents
YUKA FactoryYUKA Facility
YUKA in Shanghai ComVac Asia & Hannover Messe Exhibition
YUKA DeliveryYUKA service:
a. Providing professional consultation, technical support and special solutions
b. Providing timely feedback on complaints
c. Providing perfect after sales service and warranty
Q:Why choose us?
a. 22 years' practical experiences in R&D and manufacturing Compressed air treatment;
b. Founder of Compressed Air Nation Standard GB/T30475.1-2013 and GB/T30475.2-2013;
c. ISO 9001:2015, CE and product follow ISO8573-1;
d. With Germany Imported high efficiency filtration Test Instrument;
e.All goods had been 100% test before dispatched.
Frequently Asked Questions:
Q1. What kind of your company is it?
We're the manufacturer integrated with R&D, production and sales.
Q2. How about your technical conditions and production capability?
Complete process documents and equipment, mass production.
Q3. What is the delivery time?
Delivery time depends on the order quantity, normally is 3-5 working days after 30% payment.
Q4. Do you have a warranty?
Yes, for filter, it is 1 year normally.
Q5. Can you supply customized product?
Yes, we have a professional technical team to provide you with the best solution and complete production processes and control to provide you with satisfied product.
Address:
6th Floor, Building 2, No. 8, Qinglan 1st Road, Kengzi Street, Pingshan New District, Shenzhen
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Industrial Equipment & Components, Instruments & Meters, Manufacturing & Processing Machinery
Management System Certification:
ISO 9001
Company Introduction:
Hongrijia Depurate Facility Science & Technology Co., Ltd. Was established in 1998 and is located in Pingshan Hi-Tech Park, Shenzhen City, Guangdong Province. Production area more than 11, 000 square meters. We are manufacturer of the machine, compressed air precision filtration equipment, pneumatic components, own brand "YUKA" and With Multi National Invention and Utility model patents and IS09001: 2015 management system certification, and also be recognized as a national high-tech enterprise.
Products are widely used in defense military industry, petroleum, chemical industry, metallurgy, electricity, machinery, light industry, textile, automobile manufacturing, electronics, food, medicine, biochemical, scientific and technological research and other fields that require compressed air purification.
At the same time, as the main drafting and formulation unit, Hongrijia has formulated the national standard GB / T30475.1-2013 on the suspension oil test method and GB / T30475.2-2013 oil vapor test method; Industry standard JB / T 2953-2013 compressed air system Cyclone air-water separator and JG / T13346-2017 compressed air filter.
The revitalization of the Chinese Nation′s Modern industry and human health is Hong Rijia′s business and the responsibility of every Hong Rijia People. All Hongrijia people will continue to learn and absorb advanced technology and excellent management experience at National and abroad. For Hongrijia′s tomorrow, let′s work hard together.